LOW PRESSURE STEAM GENERATORS
STEAM ENGINEERING STEAM GENERATORS
DIRECT FIRED HIGH EFFICIENCY INDUSTRIAL STEAM GENERATORS
Our low-pressure steam generator features a robust mixer-burner integrated with a durable, refractory-lined combustion chamber. This design delivers superior safety, efficiency, and numerous advantages over traditional steam generation systems.
The process begins by forcing air and fuel into the mixer-burner, where the mixture is ignited upon entering the combustion chamber for complete (100%) combustion. As the hot exhaust gases exit the chamber, water is precisely sprayed in, producing instant steam on demand.
A key efficiency boost comes from harnessing the non-condensable stack gases—instead of venting them as waste, the system combines them with the steam to capture additional energy, significantly maximizing overall thermal performance.
MODELS LISTED BELOW
-
SPECIFICATIONS
STEAM OUTPUT PRESSURE - 0.1 PSIG - 6 PSIG (6)
NATURAL GAS (OPTION 1) - Maximum 1000 Cubic Ft/Hr Flow Rate @ 7-14 PSIG (3)
PROPANE (OPTION 2) - Maximum 9 Gallons/Hr Vaporized Flow Rate @ 7-14 PSIG (3)
OIL FIRED (OPTION 3) - Maximum 6.1 Gallons/Hr Flow Rate
WATER COMSUMPTION - Maximum 1.2 Gallons/Min Flow Rate @ 40 PSIG
ELECTRICAL REQUIREMENTS - 13A 460V / 11A 575V 3PH/60/50Hz
STEAM MANIFOLD SIZE - 4” Piping Initial Connection
FIRING RATE - 400,000 - 800,000 BTU/Hr (1)(2)
DIMENSIONS - 72 Inch Length x 56 Inch Width x 68 Inch Height
STANDARD WEIGHT - 3150 LBS
Continuous Duty rated capacity.
Output Capacity can be de-rated to customer’s specifications where required.
Where required, reduced gas pressures of 5 PSIG may be used after review by Steam Engineering.
When containerized, electrical input for 460VAC and 575VAC units are 100 amp service.
Steam Pressure is not correlated to traditional steam tables for temperature, but is directly correlated to the downstream piping size and material resistances the blower pushes against. Pressures greater than specified will result in an emergency stop of the appliance.
-
SPECIFICATIONS
STEAM OUTPUT PRESSURE - 0.1 PSIG - 6 PSIG (6)
GAS FIRED (OPTION 1) - Maximum 3000 Cubic Ft/Hr Flow Rate @ 7-14 PSIG (3)
PROPANE FIRED (OPTION 2) - Maximum 27 Gallons/Hr Vaporized Flow Rate @ 7-14 PSIG (3)
OIL FIRED (OPTION 3) - Maximum 18.3 Gallons/Hr Flow Rate
WATER COMSUMPTION - Maximum 3.6 Gallons/Min Flow Rate @ 40 PSIG
ELECTRICAL REQUIREMENTS - 32A 460V / 30A 575V 3PH/60/50Hz
STEAM MANIFOLD SIZE - 6” Piping Initial Connection
FIRING RATE - 1,200,000 - 2,400,000 BTU/Hr (1)(2)
DIMENSIONS - 83 Inch Length x 67.5 Inch Width x 68.46 Inch Height
STANDARD WEIGHT - 3844 LBS
Continuous Duty rated capacity.
Output Capacity can be de-rated to customer’s specifications where required.
Where required, reduced gas pressures of 5 PSIG may be used after review by Steam Engineering.
When containerized, electrical input for 460VAC and 575VAC units are 100 amp service.
Steam Pressure is not correlated to traditional steam tables for temperature, but is directly correlated to the downstream piping size and material resistances the blower pushes against. Pressures greater than specified will result in an emergency stop of the appliance.
-
SPECIFICATIONS
STEAM OUTPUT PRESSURE - 0.1 PSIG - 6 PSIG (6)
GAS FIRED (OPTION 1) - Maximum 5000 Cubic Ft/Hr Flow Rate @ 7-14 PSIG (3)
PROPANE FIRED (OPTION 2) - Maximum 44 Gallons/Hr Vaporized Flow Rate @ 7-14 PSIG (3)
OIL FIRED (OPTION 3) - Maximum 30.5 Gallons/Hr Flow Rate
WATER COMSUMPTION - Maximum 5.8 Gallons/Min Flow Rate @ 40 PSIG
ELECTRICAL REQUIREMENTS - 46A 460V / 42A 575V 3PH/60/50Hz
STEAM MANIFOLD SIZE - 8” Piping Initial Connection
FIRING RATE - 2,000,000 - 4,000,000 BTU/Hr (1)(2)
DIMENSIONS - 89.75 Inch Length x 67.5 Inch Width x 79.13 Inch Height
STANDARD WEIGHT - 5250 LBS
Continuous Duty rated capacity.
Output Capacity can be de-rated to customer’s specifications where required.
Where required, reduced gas pressures of 5 PSIG may be used after review by Steam Engineering.
When containerized, electrical input for 460VAC and 575VAC units are 100 amp service.
Steam Pressure is not correlated to traditional steam tables for temperature, but is directly correlated to the downstream piping size and material resistances the blower pushes against. Pressures greater than specified will result in an emergency stop of the appliance.
-
SPECIFICATIONS
STEAM OUTPUT PRESSURE - 0.1 PSIG - 6 PSIG (6)
GAS FIRED (OPTION 1) - Maximum 6000 Cubic Ft/Hr Flow Rate @ 7-14 PSIG (3)
PROPANE FIRED (OPTION 2) - Maximum 52.8 Gallons/Hr Vaporized Flow Rate @ 7-14 PSIG (3)
WATER COMSUMPTION - Maximum 6.7 Gallons/Min Flow Rate @ 40 PSIG
ELECTRICAL REQUIREMENTS - 52A 460V / 48A 575V 3PH/60/50Hz
STEAM MANIFOLD SIZE - 8” Piping Initial Connection
FIRING RATE - 2,400,000 - 6,000,000 BTU/Hr (1)(2)
DIMENSIONS - 123 Inch Length x 88 Inch Width x 86 Inch Height
STANDARD WEIGHT - 7640 LBS
Continuous Duty rated capacity.
Output Capacity can be de-rated to customer’s specifications where required.
Where required, reduced gas pressures of 5 PSIG may be used after review by Steam Engineering.
When containerized, electrical input for 460VAC and 575VAC units are 100 amp service.
Steam Pressure is not correlated to traditional steam tables for temperature, but is directly correlated to the downstream piping size and material resistances the blower pushes against. Pressures greater than specified will result in an emergency stop of the appliance.